This is early beta for now! Can't handle all templates properly
Hankkija
Vastaanotettu Hilmaan | 2023-06-29 |
Ilmoituksen numero | 2023-132255 |
TED numero | 2023/S 126-401904 |
Ostajaorganisaatio | University of Turku (0245896-3 ) Yliopistonmäki FI-20500 Turku http://www.utu.fi |
Hankinnan otsikkotiedot | Wide-field light microscope for combined high-speed, high-throughput, and high-resolution analysis of molecular interactions |
Hankinnan yhteenlaskettu kokonaisarvo koko ajalle (ilman alv:ta) arvio | 208 500 EUR |
Hankinnan yhteenlaskettu kokonaisarvo koko ajalle (ilman alv:ta) lopullinen | |
Alkuperäinen ilmoitus | https://www.hankintailmoitukset.fi/fi/public/procurement/90454/notice/132255/overview |
Originaali JSON tietue | 132255.json |
Ostettava
Hankinnan lyhyt kuvaus | The system to be purchased must include: 1) A versatile, future-proof, fully motorized, research grade, inverted light microscope body, equipped for both fluorescence and trans-illumination imaging, with a PC workstation and image acquisition and image post-processing software suitable for automatic, multi-colour image acquisition of 2D and 3D single position, automatic multi-position, and tiled image data sets in fluorescence mode with a high-sensitivity monochromatic CMOS camera, and in colorimetric mode with a high-sensitivity colour CCD or CMOS camera. The microscope system must include a black cage incubator with temperature and CO2 control to enable live cell imaging under physiological conditions (37C and 5% CO2). 2) A validated and demonstratable strategy for live background subtraction that enable on-the-fly adjustments of image acquisition settings in thicker samples (e.g. 50-100 µm thick tissue sections, spheroids and organoids, zebra fish embryos, and similar) that normally suffers from an overwhelming out-of-focus signal such that the in-focus signal is indistinguishable in live imaging mode. For full flexibility, the system should furthermore include validated strategies for further post-processing image enhancement by built in image de-convolution capabilities with a specific aim at tackling improvement for deep imaging in thick samples. 3) A range of research grade microscope objectives suitable for imaging a broad range of samples and sample configurations including for specialised imaging of coverslip-free mounted samples on standard 1mm thick glass slides for downstream proteomic analysis. |
Hankintanimikkeistö (CPV) pää | Microscopes (38510000) |
Hankintanimikkeistö (CPV) muut | Laboratory, optical and precision equipments (excl. glasses) (38000000) |
Aluekoodi | FI1C1 |
Pääasiallinen suorituspaikka |