This is early beta for now! Can't handle all templates properly

Hankkija

Vastaanotettu Hilmaan2023-08-18
Ilmoituksen numero2023-134717
TED numero2023/S 161-510828
OstajaorganisaatioUniversity of Oulu (0245895-5 )
Pentti Kaiteran katu 1 / PL 8000
FI-90014 OULU
http://www.oulu.fi/yliopisto/
Hankinnan otsikkotiedotInverted Microscope
Hankinnan yhteenlaskettu kokonaisarvo koko ajalle (ilman alv:ta) arvio
Hankinnan yhteenlaskettu kokonaisarvo koko ajalle (ilman alv:ta) lopullinen
Alkuperäinen ilmoitushttps://www.hankintailmoitukset.fi/en/public/procurement/91709/notice/134717/overview
Originaali JSON tietue134717.json

Ostettava

Hankinnan lyhyt kuvausUniversity of Oulu, Elbuken Lab: Microfluidics and Biosensor Research Group, requests tenders for an inverted microscope. Purpose of the investment is to monitor particle flow inside microfluidic devices that are custom-designed using microfabrication techniques. The microscope will be used to measure device dimensions, image flow profiles using fluorescent particle tracers and to record images and time lapse images. The microscope will complement the existing microscopes and will be used for long-term imaging of particle flow inside microchannels. The microscope will be used for research purposes for microfluidic system and biosensor development, e.g. . microfluidic connections are made from above for the microfluidic devices we produce. These devices are primarily made put of polymers (PDMS and PMMA) and bonded on 1mm-thick glass or PMMA. Hence, at least 5 cm working space is needed above the devices, thus an inverted microscope is needed. Both mm-scale channel features and micron-scale particle flow will be monitored, hence a range of magnification options are required to cover at least range from 2,5x to 65x. Imaging will be done using multiple cameras, including the existing high speed camera, hence multiple camera port options and simultaneous imaging from two cameras is required, one being the existing high speed camera. A color camera is needed for imaging. A high sensitivity monochromatic camera is required for fluorescent imaging. Multiple types of particles will be imaged, hence brightfield, fluorescent, polarization and DIC contrast options are needed. Phase contrast is not needed. Automated turret change is not needed. R,G,B and UV ranges should be covered for fluorescent imaging with proper light source and filter set combinations. A desktop computer with screen is available, hence the software should be installed to the existing desktop. Software is required to control the motorized capability, x-y and z direction movement. The microscope needs to be available for further upgrades, such as higher automation, confocal imaging, Raman imaging, hence an upgradable chassis is required. Expected value of the acquisition is 75.000-130.000 € (VAT 0 %). Later on, the value may be more than 215.000 € (VAT 0 %) including options and other unspecified additional costs of additional features in the future when upgrading of the microscope is needed. The future upgrades (options) do not affect the tender price comparison.
Hankintanimikkeistö (CPV) pääInverted microscopes (38513100)
Hankintanimikkeistö (CPV) muut
AluekoodiFI1D9
Pääasiallinen suorituspaikkaOulu

Sopimukset