{
    "id": 104924,
    "procurementProjectId": 73230,
    "noticeNumber": "2022-104924",
    "reducedTimeLimitsForReceiptOfTenders": false,
    "corrigendumAdditionalInformation": [],
    "creatorSystem": "Cloudia Kilpailutus",
    "type": 1500,
    "legalBasis": "32014L0024",
    "project": {
        "id": 73230,
        "title": "High resolution accurate mass spectrometer with ion mobility",
        "contractType": 1,
        "procurementCategory": 1,
        "jointProcurement": false,
        "procurementLaw": [],
        "centralPurchasing": false,
        "coPurchasers": [],
        "validationState": 0,
        "organisation": {
            "id": "93423d4b-26ea-4cb1-2cad-08d78deb351a",
            "information": {
                "officialName": "University of Turku",
                "nationalRegistrationNumber": "0245896-3",
                "nutsCodes": [
                    "FI1C1"
                ],
                "postalAddress": {
                    "streetAddress": "Yliopistonm\u00e4ki",
                    "postalCode": "20014",
                    "town": "Turku",
                    "country": "FI"
                },
                "telephoneNumber": "+358 503839896",
                "email": "[email protected]",
                "contactPerson": "Jaakko Uotila",
                "mainUrl": "http:\/\/www.utu.fi",
                "validationState": 0
            },
            "contractingAuthorityType": 16,
            "contractingType": 1,
            "mainActivity": 512,
            "mainActivityUtilities": 0,
            "validationState": 0,
            "dataSource": 0,
            "identifierMissing": false,
            "vhsStatus": 0
        },
        "state": 1,
        "defenceWorks": 0,
        "defenceSupplies": 0,
        "publish": 1,
        "agricultureWorks": 0,
        "isPrivate": false,
        "isConcluded": false,
        "tendering": 0
    },
    "lotsInfo": {
        "divisionLots": false,
        "lotsSubmittedFor": 0,
        "lotsSubmittedForQuantity": 0,
        "lotsMaxAwarded": false,
        "lotsMaxAwardedQuantity": 0,
        "lotCombinationPossible": false,
        "lotCombinationPossibleDescription": [],
        "validationState": 0
    },
    "objectDescriptions": [
        {
            "mainCpvCode": {
                "code": "38000000",
                "name": "Laboratory, optical and precision equipments (excl. glasses)",
                "vocCodes": []
            },
            "quantityOrScope": [],
            "additionalCpvCodes": [],
            "nutsCodes": [
                "FI1C1"
            ],
            "mainsiteplaceWorksDelivery": [
                "Turku"
            ],
            "descrProcurement": [
                "Direct award; University intends to buy a high resolution accurate mass spectrometer with ion mobility for Turku Proteomics facility, Turku Bioscience Centre, by a direct purchase."
            ],
            "disagreeAwardCriteriaToBePublished": false,
            "awardCriteria": {
                "criterionTypes": 0,
                "qualityCriteria": [],
                "costCriteria": [],
                "priceCriterion": {},
                "criterion": [],
                "criteriaStatedInProcurementDocuments": false
            },
            "estimatedValue": {
                "type": 0
            },
            "timeFrame": {
                "type": 3,
                "beginDate": "2022-07-01T00:00:00",
                "canBeRenewed": false
            },
            "candidateNumberRestrictions": {
                "envisagedNumber": 0,
                "envisagedMinimumNumber": 0,
                "envisagedMaximumNumber": 0,
                "selected": 0
            },
            "optionsAndVariants": {
                "variantsWillBeAccepted": false,
                "partialOffersWillBeAccepted": false,
                "options": false,
                "optionType": 0
            },
            "tendersMustBePresentedAsElectronicCatalogs": false,
            "euFunds": {
                "procurementRelatedToEuProgram": false
            },
            "additionalInformation": [],
            "awardContract": {
                "contractAwarded": 1,
                "noAwardedContract": {
                    "failureReason": 0,
                    "originalNoticeSentVia": 0
                },
                "awardedContracts": [
                    {
                        "conclusionDate": "2022-07-01T00:00:00",
                        "contractTitle": "High resolution accurate mass spectrometer with ion mobility",
                        "numberOfTenders": {
                            "disagreeTenderInformationToBePublished": false,
                            "total": 0,
                            "electronic": 0
                        },
                        "disagreeContractorInformationToBePublished": false,
                        "contractors": [
                            {
                                "officialName": "Thermo Fisher Scientific Oy",
                                "nationalRegistrationNumber": "0921547-0",
                                "nutsCodes": [
                                    "FI1B"
                                ],
                                "postalAddress": {
                                    "postalCode": "01620",
                                    "town": "Vantaa",
                                    "country": "FI"
                                },
                                "isSmallMediumEnterprise": false,
                                "validationState": 0
                            }
                        ],
                        "initialEstimatedValueOfContract": {
                            "value": 690000,
                            "currency": "EUR"
                        },
                        "finalTotalValue": {
                            "type": 1,
                            "value": 690000,
                            "currency": "EUR"
                        },
                        "likelyToBeSubcontracted": false,
                        "valueOfSubcontract": {},
                        "notPublicFields": {
                            "communityOrigin": false,
                            "nonCommunityOrigin": false,
                            "awardedToTendererWithVariant": false,
                            "abnormallyLowTendersExcluded": false
                        }
                    }
                ]
            },
            "validationState": 0
        }
    ],
    "communicationInformation": {
        "procurementDocumentsAvailable": 0,
        "additionalInformation": 1,
        "additionalInformationAddress": {
            "officialName": "University of Turku",
            "nationalRegistrationNumber": "0245896-3",
            "nutsCodes": [
                "FI1C1"
            ],
            "postalAddress": {
                "streetAddress": "Yliopistonm\u00e4ki",
                "postalCode": "20014",
                "town": "Turku",
                "country": "FI"
            },
            "telephoneNumber": "+358 503839896",
            "email": "[email protected]",
            "contactPerson": "Jaakko Uotila",
            "mainUrl": "http:\/\/www.utu.fi",
            "validationState": 0
        },
        "otherAddressForProcurementDocuments": {
            "nutsCodes": [],
            "postalAddress": {},
            "validationState": 0
        },
        "sendTendersOption": 0,
        "addressToSendTenders": {
            "nutsCodes": [],
            "postalAddress": {},
            "validationState": 0
        },
        "electronicCommunicationRequiresSpecialTools": false,
        "documentsEntirelyInHilma": false,
        "specsAndAdditionalDocuments": 0,
        "validationState": 0
    },
    "contactPerson": {
        "name": "Jaakko Uotila",
        "email": "[email protected]",
        "phone": "+358 503839896"
    },
    "procurementObject": {
        "shortDescription": [
            "University intends to buy a high resolution accurate mass spectrometer with ion mobility for Turku Proteomics facility, Turku Bioscience Centre, by a direct purchase."
        ],
        "estimatedValue": {
            "type": 1,
            "value": 690000,
            "currency": "EUR"
        },
        "estimatedValueCalculationMethod": [],
        "mainCpvCode": {
            "code": "38000000",
            "name": "Laboratory, optical and precision equipments (excl. glasses)",
            "vocCodes": []
        },
        "totalValue": {
            "type": 1,
            "value": 690000,
            "currency": "EUR"
        },
        "defence": {
            "nutsCodes": [],
            "frameworkAgreement": {
                "includesFrameworkAgreement": false,
                "includesConclusionOfFrameworkAgreement": false,
                "frameworkAgreementType": 0,
                "frameworkEnvisagedType": 0,
                "includesDynamicPurchasingSystem": false,
                "dynamicPurchasingSystemInvolvesAdditionalPurchasers": false,
                "dynamicPurchasingSystemWasTerminated": false,
                "estimatedTotalValue": {
                    "type": 0
                },
                "duration": {
                    "type": 0,
                    "canBeRenewed": false
                }
            },
            "subcontract": {
                "tendererHasToIndicateShare": false,
                "tendererHasToIndicateChange": false,
                "caMayOblige": false,
                "successfulTenderer": false,
                "successfulTendererToSpecify": false
            },
            "optionsAndVariants": {
                "variantsWillBeAccepted": false,
                "partialOffersWillBeAccepted": false,
                "options": false,
                "optionType": 0
            },
            "totalQuantityOrScope": {
                "type": 0
            },
            "renewals": {
                "canBeRenewed": false
            },
            "timeFrame": {
                "type": 0,
                "canBeRenewed": false
            }
        },
        "validationState": 0
    },
    "conditionsInformation": {
        "professionalSuitabilityRequirements": [],
        "economicCriteriaToParticipate": false,
        "economicCriteriaDescription": [],
        "economicRequiredStandards": [],
        "technicalCriteriaToParticipate": false,
        "technicalCriteriaDescription": [],
        "technicalRequiredStandards": [],
        "rulesForParticipation": [],
        "restrictedToShelteredWorkshop": false,
        "restrictedToShelteredProgram": false,
        "reservedOrganisationServiceMission": false,
        "depositsRequired": [],
        "financingConditions": [],
        "legalFormTaken": [],
        "qualificationSystemConditions": [],
        "ciriteriaForTheSelectionOfParticipants": [],
        "executionOfServiceIsReservedForProfession": false,
        "referenceToRelevantLawRegulationOrProvision": [],
        "participationIsReservedForProfession": false,
        "indicateProfession": [],
        "contractPerformanceConditions": [],
        "obligationToIndicateNamesAndProfessionalQualifications": false,
        "validationState": 0
    },
    "conditionsInformationDefence": {
        "depositsRequired": [],
        "financingConditions": [],
        "legalFormTaken": [],
        "otherParticularConditions": [],
        "personalSituationOfEconomicOperators": [],
        "personalSituationOfSubcontractors": [],
        "economicCriteriaOfEconomicOperators": [],
        "economicCriteriaOfEconomicOperatorsMinimum": [],
        "economicCriteriaOfSubcontractors": [],
        "economicCriteriaOfSubcontractorsMinimum": [],
        "technicalCriteriaOfEconomicOperators": [],
        "technicalCriteriaOfEconomicOperatorsMinimum": [],
        "technicalCriteriaOfSubcontractors": [],
        "technicalCriteriaOfSubcontractorsMinimum": [],
        "restrictedToShelteredWorkshops": false,
        "restrictedToShelteredProgrammes": false,
        "restrictedToParticularProfession": false,
        "restrictedToParticularProfessionLaw": [],
        "staffResponsibleForExecution": false,
        "validationState": 0
    },
    "conditionsInformationNational": {
        "participantSuitabilityCriteria": [],
        "requiredCertifications": [],
        "additionalInformation": [],
        "validationState": 0,
        "reservedForShelteredWorkshopOrProgram": false
    },
    "complementaryInformation": {
        "isRecurringProcurement": false,
        "estimatedTimingForFurtherNoticePublish": [],
        "electronicOrderingUsed": false,
        "electronicInvoicingUsed": false,
        "electronicPaymentUsed": false,
        "additionalInformation": [],
        "validationState": 0
    },
    "datePublished": "2022-07-06T06:10:09.4701297",
    "state": 2,
    "tedPublishState": 4,
    "tedSubmissionId": "20220704-005101",
    "tedPublishRequestSentDate": "2022-07-04T06:04:58",
    "tedPublicationInfo": {
        "ojs_number": "130",
        "no_doc_ojs": "2022\/S 130-369158",
        "publication_date": "2022-07-08T07:00:00",
        "ted_links": {
            "en": "http:\/\/ted.europa.eu\/udl?uri=TED:NOTICE:369158-2022:TEXT:EN:HTML"
        }
    },
    "tedValidationErrors": [
        {
            "type": "TECH",
            "items": [
                {
                    "name": "T001",
                    "valid": true,
                    "message": "XML file is valid against XSD."
                },
                {
                    "name": "T002",
                    "valid": true,
                    "message": "Metadata could be retrieved from the XML file."
                },
                {
                    "name": "T003",
                    "valid": true,
                    "message": "Unique key is active."
                }
            ]
        },
        {
            "type": "VALIDATION_RULES",
            "items": []
        }
    ],
    "noticeOjsNumber": "2022\/S 130-369158",
    "procedureInformation": {
        "procedureType": 15,
        "acceleratedProcedure": false,
        "justificationForAcceleratedProcedure": [],
        "contestType": 0,
        "frameworkAgreement": {
            "includesFrameworkAgreement": false,
            "includesConclusionOfFrameworkAgreement": false,
            "frameworkAgreementType": 0,
            "frameworkEnvisagedType": 0,
            "includesDynamicPurchasingSystem": false,
            "dynamicPurchasingSystemInvolvesAdditionalPurchasers": false,
            "dynamicPurchasingSystemWasTerminated": false,
            "estimatedTotalValue": {
                "type": 0
            },
            "duration": {
                "type": 0,
                "canBeRenewed": false
            }
        },
        "reductionRecourseToReduceNumberOfSolutions": false,
        "reserveRightToAwardWithoutNegotiations": false,
        "electronicAuctionWillBeUsed": false,
        "additionalInformationAboutElectronicAuction": [],
        "namesOfParticipantsAlreadySelected": [],
        "procurementGovernedByGPA": true,
        "criteriaForEvaluationOfProjects": [],
        "disagreeCriteriaForEvaluationOfProjectsPublish": false,
        "mainFeaturesAward": [],
        "validationState": 0
    },
    "tenderingInformation": {
        "languages": [],
        "tendersMustBeValidOption": 0,
        "tenderOpeningConditions": {},
        "defence": {
            "previousPublicationExists": false,
            "hasPreviousContractNoticeOjsNumber": false,
            "hasPreviousExAnteOjsNumber": false,
            "payableDocuments": false,
            "languageType": 0,
            "languages": [],
            "otherLanguage": false
        },
        "estimatedExecutionTimeFrame": {
            "type": 0,
            "canBeRenewed": false
        },
        "validationState": 0
    },
    "rewardsAndJury": {
        "prizeAwarded": false,
        "numberAndValueOfPrizes": [],
        "detailsOfPayments": [],
        "serviceContractAwardedToWinner": false,
        "decisionOfTheJuryIsBinding": false,
        "namesOfSelectedMembersOfJury": [],
        "validationState": 0
    },
    "resultsOfContest": {
        "contestWasTerminated": false,
        "noPrizeType": 0,
        "originalNoticeSentVia": 0,
        "participantsContemplated": 0,
        "participantsSme": 0,
        "participantsForeign": 0,
        "disagreeParticipantCountPublish": false,
        "winners": [],
        "disagreeWinnersPublish": false,
        "disagreeValuePublish": false,
        "validationState": 0
    },
    "tedNoDocExt": "2022-104924",
    "attachments": [],
    "hasAttachments": false,
    "changes": [],
    "isCorrigendum": false,
    "isMigrated": false,
    "isCancelled": false,
    "isContractAwardCancellationNotice": false,
    "cancelledReason": [],
    "isLatest": true,
    "language": "EN",
    "proceduresForReview": {
        "reviewBody": {
            "officialName": "Markkinaoikeus",
            "nutsCodes": [],
            "postalAddress": {
                "streetAddress": "S\u00f6rn\u00e4istenkatu 1",
                "postalCode": "00580",
                "town": "Helsinki",
                "country": "FI"
            },
            "telephoneNumber": "+358 295643300",
            "email": "[email protected]",
            "mainUrl": "http:\/\/www.oikeus.fi\/markkinaoikeus",
            "validationState": 0
        },
        "reviewProcedure": [],
        "validationState": 0
    },
    "attachmentInformation": {
        "description": [],
        "links": [],
        "validationState": 0
    },
    "modifications": {
        "additionalCpvCodes": [],
        "nutsCodes": [],
        "mainsiteplaceWorksDelivery": [],
        "descrProcurement": [],
        "timeFrame": {
            "type": 0,
            "canBeRenewed": false
        },
        "justificationForDurationOverFourYears": [],
        "justificationForDurationOverEightYears": [],
        "totalValue": {},
        "awardedToGroupOfEconomicOperators": false,
        "contractors": [],
        "description": [],
        "reason": 0,
        "reasonDescriptionEconomic": [],
        "reasonDescriptionCircumstances": [],
        "increaseBeforeModifications": {},
        "increaseAfterModifications": {},
        "validationState": 0
    },
    "contractAwardsDefence": [
        {
            "numberOfTenders": {
                "disagreeTenderInformationToBePublished": false,
                "total": 0
            },
            "contractor": {
                "nutsCodes": [],
                "postalAddress": {},
                "isSmallMediumEnterprise": false,
                "validationState": 0
            },
            "estimatedValue": {},
            "contractValueType": 0,
            "finalTotalValue": {},
            "lowestOffer": {},
            "highestOffer": {},
            "annualOrMonthlyValue": {
                "type": 0,
                "canBeRenewed": false
            },
            "likelyToBeSubcontracted": false,
            "valueOfSubcontract": {},
            "valueOfSubcontractNotKnown": false,
            "subcontractingDescription": [],
            "allOrCertainSubcontractsWillBeAwarded": false,
            "shareOfContractWillBeSubcontracted": false,
            "validationState": 0
        }
    ],
    "hilmaStatistics": {
        "validationState": 0
    },
    "annexes": {
        "d1": {
            "noTenders": false,
            "procedureType": 0,
            "suppliesManufacturedForResearch": false,
            "providedByOnlyParticularOperator": true,
            "reasonForNoCompetition": 1,
            "extremeUrgency": false,
            "additionalDeliveries": false,
            "repetitionExisting": false,
            "designContestAward": false,
            "commodityMarket": false,
            "advantageousTerms": false,
            "advantageousPurchaseReason": 0,
            "justification": [
                "High resolution mass spectrometers Orbitrap Exploris 480 with FAIMS, provided by Thermo Fisher",
                "Scientific, is the only instruments in the market that meet all the specific and necessary technical",
                "requirements to fulfil the uncompromising needs of the acquiring department as follows:",
                "- Our methods have been developed for Q Exactive HF Orbitrap and Orbitrap Fusion Lumos",
                "Tribrid mass spectrometers. These methods can be transferred more easily onto another",
                "Orbitrap mass spectrometer to ensure continuity.",
                "- New instrument needs to be compatible with existing Nanospray Flex Ion Source, ZipChip",
                "capillary electrophoresis system, FAIMS Pro interface, control software, and UHPLC",
                "systems in Turku Proteomics facility.",
                "- Our research consists of multiple workflows that require the use of TMTpro 18-plex",
                "reagents for maximum throughput, and therefore the new instrument needs to achieve high",
                "mass resolution (>60000 at 200m\/z), quantitative performance, and dynamic range",
                "(>5000:1 within one spectrum).",
                "- Our research utilizes SureQuant method, which the new instrument needs to support.",
                "- The new instrument must be capable of fast polarity switching, acquiring one spectrum in",
                "positive and one in negative ionization mode (one full cycle) at > 1.4 Hz at a resolution of",
                "60,000 at 200 m\/z.",
                "- New instrument needs to provide a sensitivity increase over the Q Exactive HF Orbitrap,",
                "which is traded in as a part of the payment.",
                "Estimated price paid is 581.500 \u20ac (VAT 0 %). Also as a part of the purchase and payment the old Q Exactive HF Orbitrap, estimated trade value of 108.000 \u20ac, is traded to the Supplier."
            ]
        }
    },
    "isPrivateSmallValueProcurement": false,
    "espdRequestReferences": [],
    "hilmaSubmissionDate": "2022-07-04T06:04:27.2814617",
    "dateCreated": "2022-07-04T06:04:26.9690238",
    "dateModified": "2022-07-08T07:00:04.1982371"
}